  scas451 ? february 1987 ? revised april 1993 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77001 copyright ? 1993, texas instruments incorporated 2?1 ? inputs are ttl-voltage compatible ? flow-through architecture optimizes pcb layout ? center-pin v cc and gnd configurations minimize high-speed switching noise ? epic ? (enhanced-performance implanted cmos) 1- m process ? 500-ma typical latch-up immunity at 125 c ? package options include plastic small-outline packages, ceramic chip carriers, and standard plastic and ceramic 300-mil dips description these devices contain two independent j-k positive-edge-triggered flip-flops. a low level at the preset (1pre or 2pre ) or clear (1clr or 2clr ) input sets or resets the outputs regardless of the levels of the other inputs. when pre and clr are inactive (high), data at the j and k inputs meeting the setup time requirements are transferred to the outputs on the positive-going edge of the clock pulse. clock triggering occurs at a voltage level and is not directly related to the rise time of the clock pulse. following the hold-time interval, data at the j and k inputs may be changed without affecting the levels at the outputs. these versatile flip-flops can perform as toggle flip-flops by grounding k and tying j high. they also can perform as d-type flip-flops if j and k are tied together. the 54ACT11109 is characterized for operation over the full military temperature range of ? 55 c to 125 c. the 74act11109 is characterized for operation from ? 40 c to 85 c. function table inputs outputs pre clr clk j k q q l h x x x h l h lxxxl h l lxxxh ? h ? h h lll h h h h l toggle h h lhq 0 q 0 h h hhh l h h l x x q 0 q 0 ? this configuration is nonstable; that is, it will not persist when either pre or clr returns to the inactive (high) level. 54ACT11109 ...j p ackage 74act11109 ...d or n p ackage (top view) 54ACT11109 . . . fk package (top view) nc ? no internal connection 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 1pre 1q 1q gnd 2q 2q 2pre 2clk 1clk 1k 1j 1clr v cc 2clr 2j 2k 3 2 1 20 19 910111213 4 5 6 7 8 18 17 16 15 14 2j 2k nc 2clk 2pre 1k 1clk nc 1pre 1q 1j nc 2q 2q 2clr 1q gnd nc cc v 1clr epic is a trademark of texas instruments incorporated.
scas451 ? february 1987 ? revised april 1993 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77001 2?2 logic symbol ? s 1 1j 14 1j 16 1clk c1 3 1q 2 1k 15 r 13 7 10 2j 8 2clk 5 2q 6 9 11 1pre 2pre 1clr 1k 2clr 2k 1q 2q ? this symbol is in accordance with ansi/ieee std 91-1984 and iec publication 617-12. pin numbers shown are for the d, j, and n packages. absolute maximum ratings over operating free-air temperature range (unless otherwise noted) ? supply voltage range, v cc ?0.5 v to 6 v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . input voltage range, v i (see note 1) ?0.5 v to v cc + 0.5 v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . output voltage range, v o (see note 1) ?0.5 v to v cc + 0.5 v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . input clamp current, i ik (v i < 0 or v i > v cc ) 20 ma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . output clamp current, i ok (v o < 0 or v o > v cc ) 50 ma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . continuous output current, i o (v o = 0 to v cc ) 50 ma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . continuous current through v cc or gnd 100 ma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . storage temperature range ?  65 c to 150 c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ? stresses beyond those listed under ?absolute maximum ratings? may cause permanent damage to the device. these are stress ratings only an d functional operation of the device at these or any other conditions beyond those indicated under ?recommended operating conditi ons? is not implied. exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. note 1: the input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed. recommended operating conditions 54ACT11109 74act11109 unit min max min max unit v cc supply voltage 4.5 5.5 4.5 5.5 v v ih high-level input voltage 2 2 v v il low-level input voltage 0.8 0.8 v v i input voltage 0 v cc 0 v cc v v o output voltage 0 v cc 0 v cc v i oh high-level output current ?24 ?24 ma i ol low-level output current 24 24 ma ? t/ ? v input transition rise or fall rate 0 10 0 10 ns/ v t a operating free-air temperature ?55 125 ?40 85 c
scas451 ? february 1987 ? revised april 1993 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77001 2?3 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) parameter test conditions v cc t a = 25 c 54ACT11109 74act11109 unit parameter test conditions v cc min typ max min max min max unit i oh = ? 50 a 4.5 v 4.4 4.4 4.4 i oh = ? 50 a 5.5 v 5.4 5.4 5.4 v oh i oh = ? 24 ma 4.5 v 3.94 3.7 3.8 v v oh i oh = ? 24 ma 5.5 v 4.94 4.7 4.8 v i oh = ? 50 ma ? 5.5 v 3.85 i oh = ? 75 ma ? 5.5 v 3.85 i ol = 50 a 4.5 v 0.1 0.1 0.1 i ol = 50 a 5.5 v 0.1 0.1 0.1 v ol i ol = 24 ma 4.5 v 0.36 0.5 0.44 v v ol i ol = 24 ma 5.5 v 0.36 0.5 0.44 v i ol = 50 ma ? 5.5 v 1.65 i ol = 75 ma ? 5.5 v 1.65 i i v i = v cc or gnd 5.5 v 0.1 1 1 a i cc v i = v cc or gnd, i o = 0 5.5 v 4 80 40 a ? i cc ? one input at 3.4 v, other inputs at v cc or gnd 5.5 v 0.9 1 1 ma c i v i = v cc or gnd 5 v 3.5 pf ? not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. ? this is the increase in supply current for each input that is at one of the specified ttl voltage levels rather than 0 v or v cc . timing requirements over recommended operating free-air temperature range, v cc = 5 v 0.5 v (unless otherwise noted) (see figure 1) t a = 25 c 54ACT11109 74act11109 unit min max min max min max unit f clock clock frequency 0 100 0 100 0 100 mhz t w pulse duration pre or clr low 5.5 5.5 5.5 ns t w pulse duration clk high or low 5 5 5 ns t su setup time before clk pre or clr inactive 2 2 2 ns t h hold time, data after clk 0 0 0 ns switching characteristics over recommended operating free-air temperature range, v cc = 5 v 0.5 v (unless otherwise noted) (see figure 1) parameter from to t a = 25 c 54ACT11109 74act11109 unit parameter from (input) to (output) min typ max min max min max unit f max 100 125 100 100 mhz t plh pre or clr q or q 1.5 5.5 8.6 1.5 9.8 1.5 9.2 ns t phl pre or clr q or q 1.5 6 10.8 1.5 12.6 1.5 11.8 ns t plh clk q or q 1.5 6 8.3 1.5 9.7 1.5 9.1 ns t phl clk q or q 1.5 5.5 7.6 1.5 9 1.5 8.3 ns
scas451 ? february 1987 ? revised april 1993 post office box 655303 ? dallas, texas 75265 post office box 1443 ? houston, texas 77001 2?4 operating characteristics, v cc = 5 v, t a = 25 c parameter test conditions typ unit c pd power dissipation capacitance per flip-flop c l = 50 pf, f = 1 mhz 31 pf parameter measurement information 50% v cc 1.5 v 1.5 v 1.5 v 3 v 3 v 0 v 0 v t h t su voltage waveforms data input t plh t phl t phl t plh v oh v oh v ol v ol 1.5 v 1.5 v 3 v 0 v 50% v cc 50% v cc input (see note b) out-of-phase output in-phase output timing input (see note b) 50% v cc voltage waveforms 3 v 0 v 1.5 v 1.5 v t w voltage waveforms input load circuit from output under test c l = 50 pf (see note a) 500 ? notes: a. c l includes probe and jig capacitance. b. all input pulses are supplied by generators having the following characteristics: prr 10 mhz, z o = 50 ? , t r = 3 ns, t f = 3 ns. c. the outputs are measured one at a time with one input transition per measurement. figure 1. load circuit and voltage waveforms
important notice texas instruments incorporated and its subsidiaries (ti) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. all products are sold subject to ti?s terms and conditions of sale supplied at the time of order acknowledgment. ti warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with ti?s standard warranty. testing and other quality control techniques are used to the extent ti deems necessary to support this warranty. except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. ti assumes no liability for applications assistance or customer product design. customers are responsible for their products and applications using ti components. to minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. ti does not warrant or represent that any license, either express or implied, is granted under any ti patent right, copyright, mask work right, or other ti intellectual property right relating to any combination, machine, or process in which ti products or services are used. information published by ti regarding third-party products or services does not constitute a license from ti to use such products or services or a warranty or endorsement thereof. use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from ti under the patents or other intellectual property of ti. reproduction of ti information in ti data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. reproduction of this information with alteration is an unfair and deceptive business practice. ti is not responsible or liable for such altered documentation. information of third parties may be subject to additional restrictions. resale of ti products or services with statements different from or beyond the parameters stated by ti for that product or service voids all express and any implied warranties for the associated ti product or service and is an unfair and deceptive business practice. ti is not responsible or liable for any such statements. ti products are not authorized for use in safety-critical applications (such as life support) where a failure of the ti product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of ti products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by ti. further, buyers must fully indemnify ti and its representatives against any damages arising out of the use of ti products in such safety-critical applications. ti products are neither designed nor intended for use in military/aerospace applications or environments unless the ti products are specifically designated by ti as military-grade or "enhanced plastic." only products designated by ti as military-grade meet military specifications. buyers acknowledge and agree that any such use of ti products which ti has not designated as military-grade is solely at the buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. ti products are neither designed nor intended for use in automotive applications or environments unless the specific ti products are designated by ti as compliant with iso/ts 16949 requirements. buyers acknowledge and agree that, if they use any non-designated products in automotive applications, ti will not be responsible for any failure to meet such requirements. following are urls where you can obtain information on other texas instruments products and application solutions: products applications amplifiers amplifier.ti.com audio www.ti.com/audio data converters dataconverter.ti.com automotive www.ti.com/automotive dlp? products www.dlp.com broadband www.ti.com/broadband dsp dsp.ti.com digital control www.ti.com/digitalcontrol clocks and timers www.ti.com/clocks medical www.ti.com/medical interface interface.ti.com military www.ti.com/military logic logic.ti.com optical networking www.ti.com/opticalnetwork power mgmt power.ti.com security www.ti.com/security microcontrollers microcontroller.ti.com telephony www.ti.com/telephony rfid www.ti-rfid.com video & imaging www.ti.com/video rf/if and zigbee? solutions www.ti.com/lprf wireless www.ti.com/wireless mailing address: texas instruments, post office box 655303, dallas, texas 75265 copyright ? 2009, texas instruments incorporated


▲Up To Search▲   

 
Price & Availability of 54ACT11109

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X